PRO-BUF-1

Professional NMEA
0183 Buffer

 

Adaptable NMEA 0183 Buffer with two
OPTO-isolated inputs and twelve
ISO-DriveTM outputs...

 

 

ParameterDescription
   
Power Supply
 
Input supply voltage 10 to 35 V DC
Input supply current 325mA max @ 12V DC (all outputs @ full drive into 100 ohm loads)
Input protection Continuous reverse polarity, transient overvoltage and ESD protection
Power indicator LED, Blue - indicates unit is functioning correctly
   
NMEA 0183 Port - Listener & Talker 
Number of Listener / input ports 2  isolated NMEA 0183 Listeners
Number of Talker / output ports 12 isolated NMEA 0183 Talkers
Compatibility Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible
Electrical isolation 2500 V input to ground, 1500 V output to ground using ISO-Drive™
Speed / baud rate 4800 to 38400 bps

Talker output voltage drive

>= 2.1V (differential) into 100 ohm
Talker output current drive 20 mA maximum per output
Talker output protection Short circuit and ESD
Listener input voltage tolerance -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
Listener input protection Current limited, overdrive protection to 40 VDC and ESD protection
Listener data indicator LED, Green (Flashes to indicate valid input)
Talker data indicator LED, Orange (Flashes at data rate)
   
Serial Port  
Number of input ports 1 isolated input
Number of output ports 1 isolated output
Compatibility RS422 & RS232 compatible. RS485 Listener compatible
Electrical isolation 2500 V input to ground 1500 V output to ground using ISO-Drive™
Speed / baud rate 4800 to 115200 bps
Output voltage drive >= 2.1V (differential) into 100 ohm
Output current drive 20 mA max.
Output protection Short circuit and ESD
Input voltage tolerance -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
Input protection Current limited, overdrive protection to 40 VDC and ESD protection
   
Ethernet Port  
Host interface 10/100BaseT, automatic polarity detection
Supported protocols TCP/IP for configuration and firmware updating
TCP/IP and UDP for NMEA 0183 comms*
Connector RJ45
Electrical isolation 2kV
Indicators Green - Link, Yellow - 100 Mbps
   
Mode Inputs
 
Input voltage range 0 to 35V DC
Protection Transient overvoltage and ESD protection
   
Alarm Output
 
Contacts Normally open and normally closed*
Electrical isolation 1000V between power supply and contacts
Alarm indicator LED, red indicates a valid alarm condition
   
Mechanical  
Housing material Polycarbonate / ABS blend
Flame retardancy UL94 - V0
Weight 250g
Mounting DIN rail mount (35mm top hat rail EN 50 022)
Compass safe distance TBD
Wiring terminals Pluggable 2/3 way screw or screwless connectors, 5mm pitch, 12 to 30 AWG
   
Approvals and Certifications  
EMC IEC 60945 (sections 9 & 10)
CE 2004/108/EC
Environmental protection IP44
Operating temperature  -20°C to +70°C
Storage temperature  -40°C to +85°C
Relative Humidity (RH)  0 - 80% RH
Guarantee  5 years

*Available on future release.