What are the connections on the EMU-1?

← Back

The EMU-1 has a standard M12 male, A-coded (Micro-C) connection to connect to the NMEA 2000 network and 16 screw terminal connections as follows:
– One “Power” input pair for powering the EMU-1
– Six “Gauge” inputs
– Four “Alarm” inputs
– Two “Tacho” input pairs
– Two “Auxiliary” inputs which currently aren’t in use (as of 22/02/24), but will be used for future improvements.

For more information on NMEA 2000 and how it works, please download our free guide to NMEA 2000 networking here: https://actisense.com/complete-guide-to-building-an-nmea-2000-network/