X

NGX-1 NMEA 2000® Dual Gateway

Intelligent Gateway technology enables PC interfacing and NMEA data conversion…

The NGX-1 is an intelligent multi-function gateway, combining the power of our two previous generation products (NGT-1 and    NGW-1) into one, cost effective, flexible product.

Configure the NGX-1 to operate as an NMEA 2000 <–> PC interface, or as a bi-directional NMEA 0183 <–> NMEA 2000 conversion gateway.

 

Where To Buy

STNG Cable

 

NMEA 2000 Certified logo

Full control and visibility of your vessel data using the NGX-1; 

  • View all NMEA 2000 network data on Actisense NMEA Reader. The device supports every available PGN in the NMEA 2000 standard.
  • View converted NMEA 0183 data on Actisense NMEA Reader. The device sports the largest conversion library of any gateway.
  • Easily interface with a wide range of PC applications via the NGX-1, such as TimeZero (NMEA 2000) and OpenCPN (NMEA 0183).
  • Configure the Actisense EMU-1, NGW-1 and NGX-1 via Actisense Toolkit using an NGX-1.
  • Connect legacy NMEA 0183 instruments together with new NMEA 2000 networks, greatly reducing upgrade costs.

Ordering Information
(Part number/s)

The NGX-1 is available in two versions:
NGX-1-USB: equipped with a USB cable to allow Plug and Play connectivity with a PC.

NGX-1-ISO: equipped with a bare wire open ended cable, allowing for connectivity to an NMEA 0183 device, or Serial Port / DB-9.

 

Converting legacy equipment

The most common scenario for an NGX is connecting legacy NMEA 0183 equipment, into modern NMEA 2000 systems.

A perfect example is a vessel with NMEA 0183 GPS, Wind and Depth sensors, but there’s also an NMEA 2000 network with MFDs. Getting the NMEA 0183 data onto the MFD requires the data to be converted and output as NMEA 2000 PGNs.

The NGX will receive, convert and transmit NMEA 0183 and NMEA 2000 data bi-directionally.

Cost is the main benefit here, where an NGX costs only a fraction of an NMEA 2000 GPS for example. Save money, time and space by using an NGX and leave your existing legacy equipment in place.

Connecting to a PC

On-board computers running applications such as TimeZero are becoming more common. To get the data into these NMEA 2000 programs, an interface is required between the NMEA 2000 network and the PC. The NGX will transfer all data to/from an NMEA 2000 network and PC.

Many devices also require configuration on the network, which can be done via the Actisense NGX-1 (if the manufacturer specifies our gateway). Our products such as the EMU-1, NGW-1,NGX-1 are configured via Actisense Toolkit which can be done using an NGX-1.

 

FEATURES

  • Vital NMEA 2000 diagnostic tool
  • USB version is fully isolated to prevent dangerous ground loops
  • ISO version has OPTO-isolated input and ISO-Drive™ output for safely interfacing with RS232 or RS422
  • Up to 230,400 baud data transfer rate
  • Advanced configuration using Actisense Toolkit allows Tx / Rx lists and Tx rates to be set
  • Supports Fast Heading at 10Hz
  • Multiple diagnostic LEDs

BENEFITS

  • Allows all major PC Chartplotter applications to interface with the NMEA 2000 bus
  • Provides a rule-enforcing firewall between the PC and the NMEA 2000 bus
  • Powerful diagnosis of the NMEA 2000 network using the FREE NMEA Reader software provided
  • Configure and flash-update Actisense products on the bus
  • Upgrade NMEA 0183 equipment to NMEA 2000
  • Allow NMEA 0183 devices to receive vital NMEA 2000 data
  • Use the NMEA 2000 bus to multiplex several NMEA 0183 signals together
  • Reliable, renowned bi-directional conversion engine
  • Supports a wide range of conversions including AIS
  • Easily configurable using Actisense Toolkit

 

Power Supply (NGX-1-ISO / NGX-1-USB)
Supply Voltage (NMEA 2000 Port) 9 to 30V DC
Supply Current (NMEA 2000 Port) 62mA @ 9V DC
Load Equivalent Number (LEN) 2
Power Supply (USB Variants)
Supply Voltage (NMEA 2000 Port) 9 to 30V DC
Supply Current (USB Host Port) 10mA @ 5V DC
Supply Current (NMEA 2000 Port) 62mA @ 9V DC
Load Equivalent Number (LEN) 2
NMEA 2000 Port (NGX-1-ISO / NGX-1-USB)
Speed / Baud Rate 250kbps
Connectivity M12 Male (A coded)
ISO Port (NGX-1-ISO)
Compatibility Full NMEA 0183, RS232 & RS422 compatibility. RS485 Listener compatible
Speed/Baud Rate 4800 to 230400 Baud
Output Voltage Drive >= 2.1V (differential) into 100Ω
Output Current Drive 20mA max.
Output Protection Short circuit and ESD
Input Voltage Tolerance -15V to +15V continuous -35V to +35V short term (< 1 second)
Input Protection Current limited and overdrive protection to 40VDC
Connectivity 5mm stripped and tinned wire
Cable Length 0.75m
USB Port (USB Variant)
Compatibility USB 1.1, 2.0 and 3.0
Speed / Baud Rate 4800 to 230400 Baud
Connectivity Male type A plug moulded onto cable
Cable Length 1.8m
Isolation
NMEA 2000 Port to ISO Port Uses IsoDriveTM, Hi-Pot tested to 1000V
NMEA 2000 Port to USB Port Galvanic Isolation, Hi-Pot tested to 1000V
Mechanical
Housing Material Body Flame retardant Polycarbonate
Housing Material End Caps Flame retardant PBT
Weight NGX-1-ISO 112g
Weight NGX-1-USB 113g
Approvals and Certifications
NMEA 2000 NMEA 2000 Certified
NMEA 0183 Meets IEC 61162-1 & 61162-2 Requirements
RoHS and REACH Compliant
Module Certification KCC / BQB / IC / Wi-Fi / NCC / MIC / FCC DSS / FCC DTS / SRRC / CE
EMC EN 60945:2002 Edition 4 (section 9.3)
EN 301 489-1 V2.2.3
EN 301 489-17 V3.2.4
EN 300 328 V2.2.2 Radiated Spurious Emissions
FCC Part 15b
ICES-003 Iss 7
Environmental Protection IP67
Operating Temperature -25°C to +70°C
Storage Temperature -30°C to +70°C
Recommended Humidity 0 to 93% RH @ 40°C
Guarantee 3 years, extended to 5 years upon registration

 

 

  • Sends and receives pure NMEA 2000 data
  • Configure and flash-update Actisense products on the NMEA 2000 bus
  • Use with NMEA Reader to help diagnose network problems
  • Provides a rule-enforcing firewall between a PC and an NMEA 2000 bus
  • NGX-1-USB and NGX-1-ISO versions available to suit all installations
  • Upgrade NMEA 0183 equipment to NMEA 2000
  • Allow NMEA 0183 devices to receive vital NMEA 2000 data
  • Configure using Toolkit

NETWORK DIAGRAM

 

Actisense is dedicated to providing up-to-date software and resources for our products. Here are some useful tools and documentation to help you make the most of your product:


Support

Here is a link to our Frequently Asked Questions

Need more help? Visit our Support Centre.

 

NMEA 2000 Certified logo

Full control and visibility of your vessel data using the NGX-1; 

  • View all NMEA 2000 network data on Actisense NMEA Reader. The device supports every available PGN in the NMEA 2000 standard.
  • View converted NMEA 0183 data on Actisense NMEA Reader. The device sports the largest conversion library of any gateway.
  • Easily interface with a wide range of PC applications via the NGX-1, such as TimeZero (NMEA 2000) and OpenCPN (NMEA 0183).
  • Configure the Actisense EMU-1, NGW-1 and NGX-1 via Actisense Toolkit using an NGX-1.
  • Connect legacy NMEA 0183 instruments together with new NMEA 2000 networks, greatly reducing upgrade costs.

Ordering Information
(Part number/s)

The NGX-1 is available in two versions:
NGX-1-USB: equipped with a USB cable to allow Plug and Play connectivity with a PC.

NGX-1-ISO: equipped with a bare wire open ended cable, allowing for connectivity to an NMEA 0183 device, or Serial Port / DB-9.

 

Converting legacy equipment

The most common scenario for an NGX is connecting legacy NMEA 0183 equipment, into modern NMEA 2000 systems.

A perfect example is a vessel with NMEA 0183 GPS, Wind and Depth sensors, but there’s also an NMEA 2000 network with MFDs. Getting the NMEA 0183 data onto the MFD requires the data to be converted and output as NMEA 2000 PGNs.

The NGX will receive, convert and transmit NMEA 0183 and NMEA 2000 data bi-directionally.

Cost is the main benefit here, where an NGX costs only a fraction of an NMEA 2000 GPS for example. Save money, time and space by using an NGX and leave your existing legacy equipment in place.

Connecting to a PC

On-board computers running applications such as TimeZero are becoming more common. To get the data into these NMEA 2000 programs, an interface is required between the NMEA 2000 network and the PC. The NGX will transfer all data to/from an NMEA 2000 network and PC.

Many devices also require configuration on the network, which can be done via the Actisense NGX-1 (if the manufacturer specifies our gateway). Our products such as the EMU-1, NGW-1,NGX-1 are configured via Actisense Toolkit which can be done using an NGX-1.

 

FEATURES

  • Vital NMEA 2000 diagnostic tool
  • USB version is fully isolated to prevent dangerous ground loops
  • ISO version has OPTO-isolated input and ISO-Drive™ output for safely interfacing with RS232 or RS422
  • Up to 230,400 baud data transfer rate
  • Advanced configuration using Actisense Toolkit allows Tx / Rx lists and Tx rates to be set
  • Supports Fast Heading at 10Hz
  • Multiple diagnostic LEDs

BENEFITS

  • Allows all major PC Chartplotter applications to interface with the NMEA 2000 bus
  • Provides a rule-enforcing firewall between the PC and the NMEA 2000 bus
  • Powerful diagnosis of the NMEA 2000 network using the FREE NMEA Reader software provided
  • Configure and flash-update Actisense products on the bus
  • Upgrade NMEA 0183 equipment to NMEA 2000
  • Allow NMEA 0183 devices to receive vital NMEA 2000 data
  • Use the NMEA 2000 bus to multiplex several NMEA 0183 signals together
  • Reliable, renowned bi-directional conversion engine
  • Supports a wide range of conversions including AIS
  • Easily configurable using Actisense Toolkit

 

Power Supply (NGX-1-ISO / NGX-1-USB)
Supply Voltage (NMEA 2000 Port) 9 to 30V DC
Supply Current (NMEA 2000 Port) 62mA @ 9V DC
Load Equivalent Number (LEN) 2
Power Supply (USB Variants)
Supply Voltage (NMEA 2000 Port) 9 to 30V DC
Supply Current (USB Host Port) 10mA @ 5V DC
Supply Current (NMEA 2000 Port) 62mA @ 9V DC
Load Equivalent Number (LEN) 2
NMEA 2000 Port (NGX-1-ISO / NGX-1-USB)
Speed / Baud Rate 250kbps
Connectivity M12 Male (A coded)
ISO Port (NGX-1-ISO)
Compatibility Full NMEA 0183, RS232 & RS422 compatibility. RS485 Listener compatible
Speed/Baud Rate 4800 to 230400 Baud
Output Voltage Drive >= 2.1V (differential) into 100Ω
Output Current Drive 20mA max.
Output Protection Short circuit and ESD
Input Voltage Tolerance -15V to +15V continuous -35V to +35V short term (< 1 second)
Input Protection Current limited and overdrive protection to 40VDC
Connectivity 5mm stripped and tinned wire
Cable Length 0.75m
USB Port (USB Variant)
Compatibility USB 1.1, 2.0 and 3.0
Speed / Baud Rate 4800 to 230400 Baud
Connectivity Male type A plug moulded onto cable
Cable Length 1.8m
Isolation
NMEA 2000 Port to ISO Port Uses IsoDriveTM, Hi-Pot tested to 1000V
NMEA 2000 Port to USB Port Galvanic Isolation, Hi-Pot tested to 1000V
Mechanical
Housing Material Body Flame retardant Polycarbonate
Housing Material End Caps Flame retardant PBT
Weight NGX-1-ISO 112g
Weight NGX-1-USB 113g
Approvals and Certifications
NMEA 2000 NMEA 2000 Certified
NMEA 0183 Meets IEC 61162-1 & 61162-2 Requirements
RoHS and REACH Compliant
Module Certification KCC / BQB / IC / Wi-Fi / NCC / MIC / FCC DSS / FCC DTS / SRRC / CE
EMC EN 60945:2002 Edition 4 (section 9.3)
EN 301 489-1 V2.2.3
EN 301 489-17 V3.2.4
EN 300 328 V2.2.2 Radiated Spurious Emissions
FCC Part 15b
ICES-003 Iss 7
Environmental Protection IP67
Operating Temperature -25°C to +70°C
Storage Temperature -30°C to +70°C
Recommended Humidity 0 to 93% RH @ 40°C
Guarantee 3 years, extended to 5 years upon registration

 

 

  • Sends and receives pure NMEA 2000 data
  • Configure and flash-update Actisense products on the NMEA 2000 bus
  • Use with NMEA Reader to help diagnose network problems
  • Provides a rule-enforcing firewall between a PC and an NMEA 2000 bus
  • NGX-1-USB and NGX-1-ISO versions available to suit all installations
  • Upgrade NMEA 0183 equipment to NMEA 2000
  • Allow NMEA 0183 devices to receive vital NMEA 2000 data
  • Configure using Toolkit

NETWORK DIAGRAM

 

Actisense is dedicated to providing up-to-date software and resources for our products. Here are some useful tools and documentation to help you make the most of your product:


Support

Here is a link to our Frequently Asked Questions

Need more help? Visit our Support Centre.

Related Products